Water Conditioning Control SystemDealer Installation, Operation and Maintenance Manual Series 255 Valve / 960 Control

Strona 2 - Table of Contents

10Level II Parameters (Table 3)The Level II Parameters are P6 through P19 in Table 3. The Operation and Maintenance Manual for this product does not m

Strona 3 - Introduction

11Table 3 - Programming ParametersParameterName DescriptionRange of ValuesMinimum IncrementsDefault Units of MeasureNotesP6Refill controller1 to 99 1

Strona 4 - Superior Operation

12Brine Draw ValueParameter P7 is used by the control to calculate the brine draw time. The default value of 25 was selected for a “B” injector with l

Strona 5 - Installation

13Automatic RegenerationThere are two ways to have the control automatically start a regeneration: calendar override or having the control monitor the

Strona 6 - Initial Start-Up

14ServiceRemoving the ControlComplete the following steps to remove the control module for servicing:1. Unplug the wall-mount transformer.2. Shut off

Strona 7 - Connecting the Control

158. To remove the valve, remove the screw in the locking bar, Figure 15.Figure 15Figure 169. Apply downward hand pressure on the control and pull the

Strona 8 - • Capacity

164. Remove the meter adapter. Be careful not to misplace any of the O-rings.5. Use a needle-nose pliers to grasp one of the four vanes of the gland,

Strona 9

17Specifications255 Valve with 960 ControlHydrostatic Test Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 10 - Level II Parameters (Table 3)

18Pressure GraphsTested with 3/4-inch Brass ManifoldBarBarBar

Strona 11

19Control Valving IdentificationFlow DiagramsBrine (1)Inlet (2)Bypass (4)Outlet (3)Rinse Drain (5)Backwash/Drain (6)Valve Disc Operation

Strona 12 - Regeneration

2Table of ContentsIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Installation . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 15 - Preventive Maintenance

22Valve Body and Tank Adapter Module*Not ShownCodePartNo. Description Qty. CodePartNo. Description Qty.1 1000238 Valve Assembly w/o Flow Controls 1 9

Strona 16 - Calcium Hypochlorite

23Meter Adapter, Bypass Valve, Piping Boss, and Wall-Mount TransformerInletOutletDrain

Strona 17 - Specifications

24 Splicing the Low Voltage Transformer Cord1. Strip insulation from wire 5/16 inch (8 mm) from wire end.2. Insert stripped wire into barrel of connec

Strona 18 - Pressure Graphs

25TroubleshootingAlarmsThe Model 960 continuously monitors itself and sounds an alarm if it detects something wrong. The alarm is a beep that is on fo

Strona 19 - Valve Disc Operation

26Table 6 - Troubleshooting ProceduresProblem Possible Cause Solution1. Capacity display stays at 9999 even though there is water usage.a. Total syste

Strona 20

27Problem Possible Cause Solution10. Continuous regeneration. Camshaft does not stop at the end of regeneration.a. Broken projection on drive gear.b.

Strona 21

© Copyright 2000, 1999, 1997 Osmonics, Inc.Printed in the USA P/N 1017933 Rev. CProblem Possible Cause Solution15. Brine tank overflow. a. Brine va

Strona 22 - *Not Shown

3IntroductionThe Model 960 control provides sophisticated, demand-based water conditioning by incorporating a microprocessor and a water meter to elec

Strona 23

4control face plate indicates control valve position.• No dynamic seals that could cause leakage through wear or fatigue.• Control accepts Noryl brass

Strona 24

5InstallationAll plumbing must conform to local codes. Inspect the unit carefully for carrier shortage or shipping damage.Location SelectionThe follow

Strona 25 - Troubleshooting

6water pressure at the conditioner is not less than 40 psi (2.8 bar). You may elevate an additional 2 feet (61 cm) for each additional 10 psi (0.7 bar

Strona 26

75. Add water to the brine tank (initial fill). With a bucket or hose, add approximately 4 gallons (15 liters) of water to the brine tank. If the tank

Strona 27

8Note that some parameters have a single unit of measure option such as the Rinse Time which is only entered in minutes. Other parameters have dual un

Strona 28

9Note: If the calculation for the system capacity exceeds 9999 gallons (99.99 cubic meters) (P5, Capacity, divided by P3, Hardness,) the control will